Project Abstract

Kyoto Protocol  forces the states to decrease carbon emissions due to the combustion of hydrocarbon content  fuels  in the energy plants. When current technologies have been investigated, it seems that there is no any method that directly decreases carbon emissions in internal combustion engines, boilers etc. Nowadays, the best effective way for decreasing carbon emissions is  to develop methods that  increase the effective efficiency of systems.

In the last few years, carbon emissions that originates from ships have been aimed to be decreased as it is observed in the applications of energy consumers such as land facilities and transportation vehicles. After 1 January 2013, according to IMO (International Maritime Organization)  MARPOL Annex VI MEPC-63 regulation, preparing SEEMP (Ship Energy Efficiency Management Plan) has become mandatory in all ships that  is 400 gross ton and above for the purpose of controlling carbon emissions. In addition, according to MARPOL Annex VI MEPC.1/Circ.684 regulation following monitoring parameters named as EEOI (Energy Efficiency Operation Index) has been come into force.

One of the components that consume energy in ships is HVAC (Heating, Ventilating and Air Conditioning refrigeration ) System. In existing ships, refrigeration systems are designed to work according to extreme conditions and compressors work at constant speed. In these systems, sea water is  used in condenser as a coolant. While sea water temperature increases, the compressor outlet pressure must be kept higher in order to ensure condensation in condenser outlet. This causes to increase power demand of compressor by leading to decrease COP. On the other hand, when the sea water temperature decreases, the power demand of compressor decreases. In that case, It can not be benefited from energy saving potential of Ref. System  occurred in lower sea water temperature conditions.

In this project, refrigeration system having variable speed driven compressor has been set up. The purpose of this study is to investigate the energy saving potential of the variable speed driven compressor against the constant frequency on-off operated compressor by experimentation for different condenser temperatures.