Aligning the CMS muon chambers with the muon alignment system during an extended cosmic ray run


Creative Commons License

Chatrchyan S., Khachatryan V., Sirunyan A., Adam W., Arnold B., Bergauer H., ...Daha Fazla

Journal of Instrumentation, cilt.5, sa.3, 2010 (SCI-Expanded) identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 5 Sayı: 3
  • Basım Tarihi: 2010
  • Doi Numarası: 10.1088/1748-0221/5/03/t03019
  • Dergi Adı: Journal of Instrumentation
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Yıldız Teknik Üniversitesi Adresli: Hayır

Özet

The alignment system for the muon spectrometer of the CMS detector comprises three independent subsystems of optical and analog position sensors. It aligns muon chambers with respect to each other and to the central silicon tracker. System commissioning at full magnetic field began in 2008 during an extended cosmic ray run. The system succeeded in tracking muon detector movements of up to 18 mm and rotations of several milliradians under magnetic forces. Depending on coordinate and subsystem, the system achieved chamber alignment precisions of 140-350 μm and 30-200 μrad, close to the precision requirements of the experiment. Systematic errors on absolute positions are estimated to be 340-590 μm based on comparisons with independent photogrammetry measurements. © 2010 IOP Publishing Ltd and SISSA.