Optimization of paper mill industry wastewater treatment by electrocoagulation and electro-Fenton processes using response surface methodology


Guvenc S., ERKAN H., VARANK G., BİLGİLİ M. S., ENGIN G. O.

WATER SCIENCE AND TECHNOLOGY, cilt.76, sa.8, ss.2015-2031, 2017 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 76 Sayı: 8
  • Basım Tarihi: 2017
  • Doi Numarası: 10.2166/wst.2017.327
  • Dergi Adı: WATER SCIENCE AND TECHNOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.2015-2031
  • Anahtar Kelimeler: cost analysis, electrocoagulation, electro-Fenton, paper mill industry wastewater, response surface methodolgy, ALUMINUM ELECTRODES, ANAEROBIC TREATMENT, OXIDATION PROCESSES, ACTIVATED CARBON, REMOVAL, PULP, EFFLUENT, COAGULATION, COD, DECOLORIZATION
  • Yıldız Teknik Üniversitesi Adresli: Evet

Özet

This study deals with chemical oxygen demand (COD), phenol and Ca+2 removal from paper mill industry wastewater by electrocoagulation (EC) and electro-Fenton (EF) processes. A response surface methodology (RSM) approach was employed to evaluate the effects and interactions of the process variables and to optimize the performance of both processes. Significant quadratic polynomial models were obtained (R-2 = 0.959, R-2 = 0.993 and R-2 = 0.969 for COD, phenol and Ca+2 removal, respectively, for EC and R-2 = 0.936, R-2 = 0.934 and R-2 = 0.890 for COD, phenol and Ca+2 removal, respectively). Numerical optimization based on desirability function was employed; in a 27.55 min trial, 34.7% of COD removal was achieved at pH 9 and current density 96 mA/cm(2) for EC, whereas in a 30 min trial, 74.31% of COD removal was achieved at pH 2 and current density 96 mA/cm(2) and H2O2/COD molar ratio 2.0 for EF. The operating costs were calculated to be 6.44 (sic)/m(3) for EC and 7.02 (sic)/m(3) for EF depending on energy and electrode consumption at optimum conditions. The results indicate that the RSM is suitable for the design and optimization of both of the processes. However, EF process was a more effective technology for paper mill industry wastewater treatment as compared with EC.