International Journal of Global Warming, cilt.7, sa.3, ss.395-408, 2015 (SCI-Expanded, Scopus)
In this study, annual, monthly and hourly ambient temperature distributions are determined and analysed for Karabük in Turkey. For each month of the year, variance of outdoor air temperature, monthly and seasonal heating degree hour (HDH) values are calculated according to 11 different indoor reference temperature (18C to 28C), and the resulting coefficient of determination indicates high correlation as R2 = 0.998. By considering HDH values, three kinds of fossil energy resources, (coal, natural gas, fuel-oil), annual unit area fuel needs, amount of carbon-dioxide and sulphur-dioxide. When indoor temperature is chosen 19C instead of 18C for coal, annual CO2 emission increases by 8.7%. On the other hand, 24C indoor temperature, rate of increase reaches to 53.2%. This study is first in the literature to investigate the effect of three kinds of fuel's energy impact on environment in the case of different indoor reference temperature for heating.