Comparative Loss Analysis of Forward Converters


Zeren T., BAKAN A. F.

2025 16th International Conference on Electrical and Electronics Engineering, ELECO 2025, İstanbul, Türkiye, 27 - 29 Kasım 2025, (Tam Metin Bildiri)

  • Yayın Türü: Bildiri / Tam Metin Bildiri
  • Doi Numarası: 10.1109/eleco69582.2025.11329309
  • Basıldığı Şehir: İstanbul
  • Basıldığı Ülke: Türkiye
  • Yıldız Teknik Üniversitesi Adresli: Evet

Özet

The efficiency and sustainability need in energy conversion has increased the importance of switch-mode power supplies (SMPS) compared to linear supplies. Among isolated SMPS topologies, the classical forward converter remains widely used. However, it requires resetting the transformer's magnetizing energy. Conventional reset methods increase losses and limit the duty cycle. Moreover, unidirectional flux utilization enlarges transformer size. The active clamp forward converter overcomes these limitations by enabling bidirectional flux, reducing transformer size, increasing duty ratio, and achieving zero voltage switching (ZVS). In this study, classical forward converter (CFC), two switch forward converter (TSFC), and active clamp forward converter (ACFC) were designed with identical parameters in two different switching frequency. Transformer area-product (AP) was calculated for each converter which indicated a smaller transformer for ACFC. Later LTspice simulations showed that ACFC's switching losses were 32.5% lower than CFC's and 48.8% lower than TSFC's, yielding higher efficiency and reduced thermal stress overall.