The effect of short columns on the performance of existing buildings


Kocak A.

STRUCTURAL ENGINEERING AND MECHANICS, cilt.46, ss.505-518, 2013 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 46
  • Basım Tarihi: 2013
  • Doi Numarası: 10.12989/sem.2013.46.4.505
  • Dergi Adı: STRUCTURAL ENGINEERING AND MECHANICS
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.505-518
  • Yıldız Teknik Üniversitesi Adresli: Evet

Özet

In this study, the seismic performance of a residential building which was damaged in the 1992 Erzincan (Turkey) Earthquake (Ms = 6.8) is performed. Damages on columns due to short columns are estimated analytically implementing the shear hinges and results are compared with the observed damages on the building after the earthquake. In seismic performance evaluation, a deformation based approach is adopted, whereby the structural behavior under external and seismic loads is evaluated. Furthermore, the effects of short columns formed by band windows in basement floors are investigated analytically. The sizes of band windows are parametrically changed in order to understand the effects of short columns on overall building behavior.