From ice to insight: A rapid and sensitive GC-MS determination of selected phthalate esters in antarctic water via switchable solvent liquid phase microextraction
Microchemical Journal, cilt.231, 2026 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 231
- Basım Tarihi: 2026
- Doi Numarası: 10.1016/j.microc.2026.119914
- Dergi Adı: Microchemical Journal
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, BIOSIS, Chemical Abstracts Core, Chimica, Index Islamicus, Academic Search Ultimate (EBSCO), Engineering Source (EBSCO)
- Anahtar Kelimeler: Antarctica, Environmental pollution, Phthalate esters, Switchable solvent-liquid phase microextraction
- Yıldız Teknik Üniversitesi Adresli: Evet
Özet
Environmental pollution has increased considerably in recent decades as a result of anthropogenic activities; therefore, monitoring of environmental contamination is essential to safeguard ecosystems and protect public health. Phthalate esters (PEs) are among the most persistent and toxic organic contaminants; hence, their accurate determination at trace levels is of great importance. This study presents a gas chromatography–mass spectrometry (GC-MS) method coupled with a switchable solvent-liquid phase microextraction (SS-LPME) for the quantification of dimethyl phthalate (DMP), diallyl phthalate (DAP), dipropyl phthalate (DPP), dibutyl phthalate (DBP) and dioctyl phthalate (DOP) at trace levels. SS-LPME offers a single-solvent, dispersant-free alternative to conventional dispersive liquid-liquid microextraction (DLLME) methods, which typically rely on toxic chlorinated extractants such as chloroform, dichloromethane and 1,2-dichloroethane. A one-at-a-time optimization approach was utilized to improve the quantification capability of the GC-MS system. The developed SS-LPME-GC-MS method demonstrated great analytical figures of merits for all target analytes, with detection/quantification limits of 0.36/1.20 μg/kg, 0.55/1.84 μg/kg, 0.14/0.47 μg/kg, 0.05/0.15 μg/kg and 0.35/1.16 μg/kg for DMP, DAP, DPP, DBP and DOP, respectively. Following the integration of SS-LPME, the quantification capability of the GC-MS system for DMP, DAP, DPP, DBP and DOP was enhanced by 187-fold, 542-fold, 473-fold, 4113-fold and 590-fold, respectively. Recovery experiments were performed using spiked environmental water samples collected from Antarctica and Türkiye, and satisfactory recovery values ranging from 88.7% to 125.6% confirmed the applicability of the developed method.