Parallel operation characteristics of PEM fuel cell and microturbine power plants


Uzunoglu M., ONAR O., EL-SHARKH M. Y., SISWORAHARDJO N. S., RAHMAN A., ALAM M. S.

JOURNAL OF POWER SOURCES, cilt.168, sa.2, ss.469-476, 2007 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 168 Sayı: 2
  • Basım Tarihi: 2007
  • Doi Numarası: 10.1016/j.powsour.2007.03.038
  • Dergi Adı: JOURNAL OF POWER SOURCES
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Sayfa Sayıları: ss.469-476
  • Yıldız Teknik Üniversitesi Adresli: Hayır

Özet

This paper reports on the dynamic behavior of a 250 kW proton exchange membrane fuel cell power plant (PEM FCPP) and a 250 kW microturbine (MT) when operating in parallel. A load sharing control scheme is used to distribute the load equally between the PEM FCPP and the MT. For stand alone operation of a PEM FCPP, a set of batteries or ultracapacitors are needed in order to satisfy the power mismatch during transient periods. Using MT in parallel with the PEM FCPP helps in eliminating the need for storage devices. Models for the PEM FCPP and the MT with power, voltage and speed controls are used to determine the dynamic response of the system to a step change in the load. Simulation results indicate viability of parallel operation of the PEM FCPP and the MT. These results are obtained using MATLAB (R), Simulink (R), and SimpowerSystems (R). (C) 2007 Elsevier B.V. All rights reserved.