Visual, refractive and topographic outcomes of progressive thickness intrastromal corneal ring segments for keratoconic eyes


Coskunseven E., Ambrosio R., Smoradkova A., Sanchez Leon F., Sahin O., Kavadarli I., ...Daha Fazla

INTERNATIONAL OPHTHALMOLOGY, cilt.40, sa.11, ss.2835-2844, 2020 (SCI-Expanded) identifier identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 40 Sayı: 11
  • Basım Tarihi: 2020
  • Doi Numarası: 10.1007/s10792-020-01467-5
  • Dergi Adı: INTERNATIONAL OPHTHALMOLOGY
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Agricultural & Environmental Science Database, BIOSIS, EMBASE, MEDLINE
  • Sayfa Sayıları: ss.2835-2844
  • Anahtar Kelimeler: Intrastromal corneal ring segments, Keratoconus, Progressive thickness intrastromal corneal ring segments, ICRS, IMPLANTATION, INTACS, PERFORMANCE
  • Yıldız Teknik Üniversitesi Adresli: Hayır

Özet

Purpose To evaluate one-year visual, refractive, and topographic outcomes of 58 eyes of 53 keratoconus patients who underwent surgery with a progressive thickness intrastromal corneal ring segment (ICRS). Methods This multi-center, retrospective, observational study evaluates the one-year effects of progressive thickness ICRS implanted in keratoconus patients meeting the inclusion criteria. One or two progressive ICRS were implanted in the selected eyes after creating an intrastromal tunnel with a femtosecond laser. Pre- and postoperative uncorrected distance visual acuity, best-corrected distance visual acuity, manifest refraction (both spherical equivalent and cylindrical refractions), corneal astigmatism, maximum keratometry, corneal thickness, and corneal topography measurements and indices were evaluated. Results In this retrospective case series, 58 eyes of 53 keratoconus patients were included with a follow-up of 12 months. The mean age was 30.89 +/- 11.90 years. There were improvements postoperatively in mean values of visual acuities, both uncorrected from 0.71 (preoperatively) to 0.28 (log MAR), and best-corrected from 0.28 to 0.10 (log MAR), mean cylindrical refraction from - 2.35 +/- 1.51 to - 4.15 +/- 2.23 D, and mean spherical equivalent from - 2.10 +/- 2.25 to - 4.64 +/- 3.2 D. There was also a reduction in maximal keratometry from 54.21 D preoperatively to 50.93 D postoperatively. Conclusion The implantation of the progressive thickness ICRS is an effective and safe method to improve the vision of keratoconic eyes. Corneal stability was maintained at the 12-month mark.