Preconcentration of bismuth using nickel hydroxide nanoflower from water samples and determination by FAAS


YILDIZ O. B., Durukan İ., Şaylan M., Zaman B. T., BAKIRDERE S.

Environmental Monitoring and Assessment, cilt.197, sa.1, 2025 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 197 Sayı: 1
  • Basım Tarihi: 2025
  • Doi Numarası: 10.1007/s10661-024-13600-3
  • Dergi Adı: Environmental Monitoring and Assessment
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, ABI/INFORM, Agricultural & Environmental Science Database, Aqualine, Aquatic Science & Fisheries Abstracts (ASFA), BIOSIS, CAB Abstracts, Compendex, EMBASE, Environment Index, Food Science & Technology Abstracts, Geobase, Greenfile, Pollution Abstracts, Public Affairs Index, Veterinary Science Database, Civil Engineering Abstracts
  • Anahtar Kelimeler: Bismuth, Flame atomic absorption spectrometry, Ni(OH)2 nanoflowers, Spring water, Tap water
  • Yıldız Teknik Üniversitesi Adresli: Evet

Özet

In this study, a preconcentration strategy based on Ni(OH)2 nanoflowers (NFs) was developed for the extraction/separation of bismuth ions from environmental water samples before the determination by flame atomic absorption spectrometry (FAAS). The homogeneous coprecipitation method was employed for the synthesis of the flower-shaped Ni(OH)2 and used as an adsorbent for the preconcentration of bismuth. The extraction variables were determined by a univariate optimization strategy to obtain maximum extraction performance. The optimal parameters of the method were as follows: 15 min mechanical shaking at 120 rpm, pH 6.0 buffer solution (1.0 mL), 20 mg of sorbent, and 250 µL of 6.0 M nitric acid for the elution. Under the optimized instrumental and extraction conditions, LOD (limit of detection), LOQ (limit of quantitation), and linear dynamic range were determined as 2.8 µg/L, 9.4 µg/L, and 0.010–0.30 mg/L, respectively. The enhancement factor of the sorbent-based method was calculated as 139.1-folds by comparing the slopes of calibration plots obtained from FAAS and the preconcentration method. To assess the feasibility and reliability of the developed method, tap water and spring water samples were analyzed under optimized conditions. The satisfactory %recoveries were obtained close to 100% using the direct comparison method. The obtained results show that the presented method is a promising candidate for efficient extraction and trace determination of bismuth in several sample mediums.